Show simple item record

dc.contributor.authorRais, Bushra
dc.contributor.authorKöster, Mario
dc.contributor.authorRahim, Muhammad Imran
dc.contributor.authorPils, Marina
dc.contributor.authorSeitz, Jan-Marten
dc.contributor.authorHauser, Hansjörg
dc.contributor.authorWirth, Dagmar
dc.contributor.authorMueller, Peter P
dc.date.accessioned2016-08-23T13:59:38Z
dc.date.available2016-08-23T13:59:38Z
dc.date.issued2016-09
dc.identifier.citationEvaluation of the inflammatory potential of implant materials in a mouse model by bioluminescent imaging of intravenously injected bone marrow cells. 2016, 104 (9):2149-58 J Biomed Mater Res Aen
dc.identifier.issn1552-4965
dc.identifier.pmid27102724
dc.identifier.doi10.1002/jbm.a.35758
dc.identifier.urihttp://hdl.handle.net/10033/618672
dc.description.abstractTo evaluate the inflammatory potential of implants a bioluminescent imaging assay was developed using luciferase-expressing bone marrow cells that were injected into the blood circulation of wild-type mice. After subcutaneous implantation of titanium discs as an example for a clinically established biocompatible material, the luminosity was modest. Similarly, low luminosity signals were generated by pure magnesium implants that were used to represent metallic alloys that are presently under investigation as novel degradable implant materials. Increased luminosity was observed in response to degradable polymeric PLGA implants. Surgical wounds induced a basic luminescent response even in the absence of an implant. However, the material-independent response to injury could be minimized using injectable microparticle suspensions. In parallel with the resorption of biodegradable microparticles, the signal induced by PLGA declined faster when compared to non-degradable polystyrene suspensions. By using an interferon type I inducible Mx2 promoter construct to drive luciferase gene expression, the highest luminosity was observed in response to bacteria, indicating that the system could also be employed to monitor implant infections. Overall, labeled bone marrow cells yielded specific, well-defined localized signals that correlated with the inflammatory responses to implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2149-2158, 2016.
dc.language.isoenen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.titleEvaluation of the inflammatory potential of implant materials in a mouse model by bioluminescent imaging of intravenously injected bone marrow cells.en
dc.typeArticleen
dc.contributor.departmentHelmholtz Centre for infection research, Inhoffenstr. 7,38124 Braunschweig, Germany.en
dc.identifier.journalJournal of biomedical materials research. Part Aen
refterms.dateFOA2017-05-15T00:00:00Z
html.description.abstractTo evaluate the inflammatory potential of implants a bioluminescent imaging assay was developed using luciferase-expressing bone marrow cells that were injected into the blood circulation of wild-type mice. After subcutaneous implantation of titanium discs as an example for a clinically established biocompatible material, the luminosity was modest. Similarly, low luminosity signals were generated by pure magnesium implants that were used to represent metallic alloys that are presently under investigation as novel degradable implant materials. Increased luminosity was observed in response to degradable polymeric PLGA implants. Surgical wounds induced a basic luminescent response even in the absence of an implant. However, the material-independent response to injury could be minimized using injectable microparticle suspensions. In parallel with the resorption of biodegradable microparticles, the signal induced by PLGA declined faster when compared to non-degradable polystyrene suspensions. By using an interferon type I inducible Mx2 promoter construct to drive luciferase gene expression, the highest luminosity was observed in response to bacteria, indicating that the system could also be employed to monitor implant infections. Overall, labeled bone marrow cells yielded specific, well-defined localized signals that correlated with the inflammatory responses to implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2149-2158, 2016.


Files in this item

Thumbnail
Name:
Rais et al.pdf
Size:
369.3Kb
Format:
PDF
Description:
original manuscript
Thumbnail
Name:
Figures_manuscript. free Prism ...
Size:
89.57Mb
Format:
Microsoft PowerPoint 2007
Description:
figures to the manuscript

This item appears in the following Collection(s)

Show simple item record

http://creativecommons.org/licenses/by-nc-sa/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-sa/4.0/