The zlog value as a basis for the standardization of laboratory results
Name:
Hoffman et al.pdf
Size:
1.131Mb
Format:
PDF
Description:
after embargo allowed publisher's ...
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
2017-01-26
Metadata
Show full item recordAbstract
Abstract Background: With regard to the German E-Health Law of 2016, the German Society for Clinical Chemistry and Laboratory Medicine (DGKL) has been invited to develop a standard procedure for the storage and transmission of laboratory results. We suggest the commonly used z-transformation. Methods: This method evaluates by how many standard deviations (SDs) a given result deviates from the mean of the respective reference population. We confirm with real data that laboratory results of healthy individuals can be adjusted to a normal distribution by logarithmic transformation. Results: Thus, knowing the lower and upper reference limits LL and UL, one can transform any result x into a zlog value using the following equation: $\eqalign{ {\rm{zlog}} = & {\rm{(log(x)}}-{\rm{(log(LL)}} + {\rm{log(UL))/2)\cdot3}}{\rm{.92/(log(UL)}} \cr -{\bf{ }}{\rm{log(LL))}} \cr} $ The result can easily be interpreted, as its reference interval (RI) is –1.96 to +1.96 by default, and very low or high results yield zlog values around –5 and +5, respectively. For intuitive data presentation, the zlog values may be transformed into a continuous color scale, e.g. from blue via white to orange. Using the inverse function, any zlog value can then be translated into the theoretical result of an analytical method with another RI: (1) $${\rm{x}} = {\rm{L}}{{\rm{L}}^{0.5 - {\rm{zlog}}/3.92}} \cdot {\rm{U}}{{\rm{L}}^{0.5 + {\rm{zlog}}/3.92}}$$ Conclusions: Our standardization proposal can easily be put into practice and may effectively contribute to data quality and patient safety in the frame of the German E-health law. We suggest for the future that laboratories should provide the zlog value in addition to the original result, and that the data transmission protocols (e.g. HL7, LDT) should contain a special field for this additional value.Citation
The zlog value as a basis for the standardization of laboratory results 2017, 41 (1) LaboratoriumsMedizinAffiliation
Helmholtz-Zentrum für Infektionsforschung GmbH, Inhoffenstr. 7, 38124 Braunschweig, Germany.Journal
LaboratoriumsMedizinAdditional Links
http://www.degruyter.com/view/j/labm.2017.41.issue-s1/labmed-2017-0135/labmed-2017-0135.xmlType
ArticleISSN
1439-04770342-3026
ae974a485f413a2113503eed53cd6c53
10.1515/labmed-2017-0135
Scopus Count
The following license files are associated with this item:
- Creative Commons
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-sa/4.0/