Issue Date
1991Submitted date
2024-01-24
Metadata
Show full item recordAbstract
Developments in bioprocess control include improvement of online measurements and control. Accuracy and precision of control or availability of the chemostat systems have reached a very high level. Measurement and control is based on new software concepts providing automatic control of complex physiological investigations or bioprocess development work. Results from cell cyele studies on yeasts synchronized growth, repetitive batch methods, medium design and integrated process layout for the production of rhamnolipids and enantiomerically pure compounds are reported. It is concluded that the breakthrough described in combination with FIA-coupling are the prerequisites for in vivo studies of the livingcells.Citation
Flow Injection Analysis (FIA) Based On Enzymes Or Antibodies, 11 - 17Affiliation
Institute of Biotechnology ETH-Hönggerberg CH 8093 ZürichType
Book chapterconference paper
Language
enSeries/Report no.
GBF monographs ; Volume 14ISSN
0930-4320ISBN
15608112183527282491
Collections
The following license files are associated with this item:
- Creative Commons
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International